Using the calculator above
Choose SI or US customary units, then enter three things:
- Runoff coefficient C, between 0 and 1. With “One C”, type a value or look one up by land use; the same values are in the table on this page. With “Area-weighted C”, list each land use with its area and coefficient, and the calculator weights them by area.
- Rainfall intensity i, in mm/h (SI) or in/h (US), for a storm lasting the catchment’s time of concentration at your design return period.
- Catchment area A, in hectares or km² (SI), or acres or square miles (US).
The peak flow comes back in m³/s and L/s, or in cfs and US gallons per minute, with the substitution written out. The calculator warns when C is above 0.95, when the intensity is above 300 mm/h, and when the area exceeds the 15 km² advisory limit in the SANRAL Drainage Manual.
The rational method formula
| Symbol | Meaning | SI | US customary |
|---|---|---|---|
| Peak discharge at the outlet | m³/s | ft³/s (cfs) | |
| Runoff coefficient | dimensionless, 0 to 1 | dimensionless, 0 to 1 | |
| Rainfall intensity for a duration equal to | mm/h | in/h | |
| Drainage area | km² | acres |
The 3.6 comes from the units: 1 mm/h over 1 km² is 10⁶ m² × 0.001 m / 3 600 s = 1/3.6 m³/s. The method assumes that the peak occurs when the whole catchment contributes, which happens once the storm has lasted one time of concentration. Rainfall is taken as uniform in space and constant in time over that duration, and C is a fixed fraction of rainfall that becomes runoff.
For a catchment with several land uses, area-weight the coefficient:
Inputs and where they come from
C comes from land use, soil permeability and slope (table below). Measure each land-use area from an aerial image or a zoning plan. The coefficient is the input engineers argue about most, and Q moves one for one with it.
i is read from an intensity-duration-frequency (IDF) curve at a duration equal to Tc. Compute Tc with the time of concentration calculator; in urban catchments it is rarely more than an hour. The IDF curve comes from a national source such as NOAA Atlas 14 in the US or from a design rainfall analysis for the site. Return periods follow the design standard: often 1:10 years for minor stormwater drains, 1:50 for major infrastructure and 1:100 for critical facilities.
A is the area draining to the point of interest, from watershed delineation for natural catchments. In urban areas, check the hydraulic divide as well: kerbs, road camber and pipes can move water between topographic catchments.
Worked example: 35 ha residential catchment
A 35 ha (0.35 km²) catchment drains to a proposed culvert. It holds 24 ha of single-family housing, 7 ha of asphalt streets and 4 ha of parks, on medium-permeability soil and moderate slopes. Tc is 20 minutes, and the local IDF curve gives 95 mm/h for a 20-minute storm at the 1:10-year return period.
Composite coefficient, with values from the table below:
Peak discharge:
The same catchment in US units is 86.5 acres with i = 3.74 in/h. The calculator returns 150.1 cfs, which is 4.25 m³/s; the hand form Q = CiA gives 148.8 cfs, the 0.8 % difference explained in the FAQ.
Raising C by 0.05 to 0.51 raises Q to 4.71 m³/s, an 11 % increase. That sensitivity is the reason to document how C was chosen. The culvert would be sized for 4.25 m³/s at the 1:10-year level of service, with any freeboard the governing standard requires; the culvert calculator takes it from there.
Runoff coefficient table
Typical C with the range in brackets, for moderate slopes, by soil permeability. These are the values in Studio’s coefficient lookup, compiled from the ASCE Manual of Practice for urban and paved surfaces and from standard references for rural cover.
| Land use | Low permeability | Medium permeability | High permeability |
|---|---|---|---|
| Single-family residential | 0.48 (0.40–0.55) | 0.40 (0.30–0.50) | 0.32 (0.25–0.40) |
| Multi-family or townhouse | 0.60 (0.50–0.70) | 0.50 (0.40–0.60) | 0.42 (0.35–0.50) |
| Apartments or condominiums | 0.70 (0.60–0.80) | 0.60 (0.50–0.70) | 0.55 (0.45–0.65) |
| High-density residential | 0.78 (0.70–0.85) | 0.70 (0.60–0.80) | 0.65 (0.55–0.75) |
| Downtown or central business district | 0.88 (0.80–0.95) | 0.82 (0.70–0.95) | 0.78 (0.65–0.90) |
| Neighbourhood commercial | 0.68 (0.60–0.75) | 0.60 (0.50–0.70) | 0.55 (0.45–0.65) |
| Shopping centre with parking | 0.80 (0.70–0.90) | 0.70 (0.60–0.80) | 0.65 (0.55–0.75) |
| Light industrial | 0.75 (0.65–0.85) | 0.67 (0.55–0.80) | 0.60 (0.50–0.70) |
| Heavy industrial | 0.85 (0.75–0.95) | 0.77 (0.65–0.90) | 0.70 (0.60–0.80) |
| Asphalt streets | 0.88 (0.80–0.95) | 0.83 (0.75–0.92) | 0.80 (0.70–0.90) |
| Concrete paving | 0.92 (0.85–0.98) | 0.88 (0.82–0.95) | 0.86 (0.80–0.92) |
| Rooftops | 0.88 (0.80–0.95) | 0.85 (0.78–0.93) | 0.82 (0.75–0.90) |
| Gravel roads and driveways | 0.52 (0.35–0.70) | 0.42 (0.25–0.60) | 0.30 (0.15–0.45) |
| Parks and landscaped gardens | 0.22 (0.15–0.30) | 0.17 (0.10–0.25) | 0.13 (0.08–0.18) |
| Playgrounds and sports fields | 0.32 (0.25–0.40) | 0.27 (0.20–0.35) | 0.22 (0.15–0.28) |
| Cultivated row crops | 0.45 (0.35–0.55) | 0.35 (0.25–0.45) | 0.25 (0.15–0.35) |
| Pasture and grassland | 0.32 (0.20–0.45) | 0.25 (0.15–0.35) | 0.18 (0.10–0.25) |
| Natural veld, scrub or bush | 0.35 (0.20–0.50) | 0.26 (0.12–0.40) | 0.18 (0.08–0.28) |
| Forest and woodland | 0.20 (0.10–0.30) | 0.13 (0.07–0.20) | 0.10 (0.05–0.15) |
| Bare or disturbed soil | 0.57 (0.40–0.75) | 0.45 (0.30–0.60) | 0.32 (0.20–0.45) |
Steeper ground raises C: bare soil on medium-permeability soil goes from 0.35 on flat terrain to 0.55 on steep terrain, and single-family housing from 0.35 to 0.45.
Limitations and when to use something else
- Peak only. There is no hydrograph and no volume, so the method cannot size storage. Build a hydrograph with the unit hydrograph generator or route a design storm through the detention pond calculator.
- Uniform rainfall. Storm cells rarely cover a large catchment evenly for the whole of Tc. Above about 15 km² the assumption becomes non-conservative, and a hydrograph or regional method is the better choice. For South African sites, design flood estimation runs the SANRAL Rational procedure next to the unit hydrograph, SDF and regional methods.
- No storage. Wetlands, dams and floodplains attenuate the peak, so the Rational Method overestimates where they are significant.
- Constant C. Real losses fall as soils wet up. Some standards raise C for rarer return periods with a frequency factor; the calculator uses the C you enter, so apply any such factor yourself.
- Tc sensitivity. Different Tc formulas give different durations and therefore different intensities.
What a free Studio account adds
Results on this page are free. A free Studio account adds:
- Saving and reports: each calculation is filed under a project, with Word and Excel reports that set out C, i, A, the formula and the warnings.
- The full coefficient lookup: 93 entries filtered by land use, slope class and soil permeability, each with its range and source.
- Composite C built from sub-areas, each with its own coefficient.
- A built-in Tc calculator with six methods to fix the storm duration, and a link to the IDF tool to read the intensity at that duration.
- An areal reduction factor on intensity, entered by hand or taken from a saved ARF calculation.
- Area from a saved watershed delineation, so the area in the report matches the mapped catchment.
Common questions
What is the rational method formula?
What runoff coefficient should I use?
What is the maximum catchment area for the rational method?
How do I choose the rainfall intensity for the rational method?
Why does the calculator give 1.008 cfs for 1 in/h on 1 acre?
Does the rational method give a runoff volume or hydrograph?
run_rational and lookup_runoff_coefficient. The agent passes the inputs, the engine does the calculation, and the record is saved to your project for you to review.
Reference tables
References
- Kuichling, E. (1889) The relation between the rainfall and the discharge of sewers in populous districts. Transactions of the American Society of Civil Engineers, 20, 1-56.
- ASCE (1992) Design and Construction of Urban Stormwater Management Systems. ASCE Manuals and Reports of Engineering Practice No. 77. American Society of Civil Engineers, New York.
- Chow, V.T., Maidment, D.R. and Mays, L.W. (1988) Applied Hydrology. McGraw-Hill, New York.
- SANRAL (2013) Drainage Manual, 6th ed. South African National Roads Agency SOC Ltd, Pretoria. Chapter 3: Hydrology.
Last reviewed by the Delta Hydro engineering team.