Free calculator · Runoff

Rational method calculator

The Rational Method estimates the peak discharge from a small catchment as runoff coefficient times rainfall intensity times area, Q = CiA. In SI units Q (m³/s) = CiA / 3.6 with i in mm/h and A in km²; in US units Q (cfs) = CiA with i in in/h and A in acres. The calculator above works in either system, and the runoff coefficient table below covers urban, paved and rural surfaces.

Rational method calculator

Runoff coefficient

0 to 1. Use the lookup below or the table in the guide.

Rainfall and catchment
mm/h

For a storm lasting the time of concentration, at the design return period.

Peak flow, Q
5.194m³/s
In litres
5 194L/s
Runoff coefficient
0.55
Q = C · i · A / 3.6
= 0.55 × 85 mm/h × 0.4 km² / 3.6
= 5.194 m³/s
Inputs used
Runoff coefficient, C0.55
Rainfall intensity, i85mm/h
Catchment area, A40ha
Catchment area in km²0.4km²
Need i? Find the storm duration with the time of concentration calculator, then read the intensity for that duration off your design rainfall (IDF) curves.

Keep this calculation

Studio accounts open soon. Join the waiting list and we'll e-mail you when you can save it in the full Rational Method tool.

  • Save to a project
  • Word and Excel report
  • Area from a delineated catchment
  • Areal reduction factor

Runs the same calculation engine as Delta Hydro Studio. Results are computed in your browser; nothing you type leaves it until you choose to save.

Using the calculator above

Choose SI or US customary units, then enter three things:

  • Runoff coefficient C, between 0 and 1. With “One C”, type a value or look one up by land use; the same values are in the table on this page. With “Area-weighted C”, list each land use with its area and coefficient, and the calculator weights them by area.
  • Rainfall intensity i, in mm/h (SI) or in/h (US), for a storm lasting the catchment’s time of concentration at your design return period.
  • Catchment area A, in hectares or km² (SI), or acres or square miles (US).

The peak flow comes back in m³/s and L/s, or in cfs and US gallons per minute, with the substitution written out. The calculator warns when C is above 0.95, when the intensity is above 300 mm/h, and when the area exceeds the 15 km² advisory limit in the SANRAL Drainage Manual.

The rational method formula

Q=C i A3.6(SI)Q = \frac{C\,i\,A}{3.6} \qquad \text{(SI)} Q=C i A(US customary)Q = C\,i\,A \qquad \text{(US customary)}
SymbolMeaningSIUS customary
QQPeak discharge at the outletm³/sft³/s (cfs)
CCRunoff coefficientdimensionless, 0 to 1dimensionless, 0 to 1
iiRainfall intensity for a duration equal to TcT_cmm/hin/h
AADrainage areakm²acres

The 3.6 comes from the units: 1 mm/h over 1 km² is 10⁶ m² × 0.001 m / 3 600 s = 1/3.6 m³/s. The method assumes that the peak occurs when the whole catchment contributes, which happens once the storm has lasted one time of concentration. Rainfall is taken as uniform in space and constant in time over that duration, and C is a fixed fraction of rainfall that becomes runoff.

For a catchment with several land uses, area-weight the coefficient:

C=∑jCj Aj∑jAjC = \frac{\sum_j C_j\,A_j}{\sum_j A_j}

Inputs and where they come from

C comes from land use, soil permeability and slope (table below). Measure each land-use area from an aerial image or a zoning plan. The coefficient is the input engineers argue about most, and Q moves one for one with it.

i is read from an intensity-duration-frequency (IDF) curve at a duration equal to Tc. Compute Tc with the time of concentration calculator; in urban catchments it is rarely more than an hour. The IDF curve comes from a national source such as NOAA Atlas 14 in the US or from a design rainfall analysis for the site. Return periods follow the design standard: often 1:10 years for minor stormwater drains, 1:50 for major infrastructure and 1:100 for critical facilities.

A is the area draining to the point of interest, from watershed delineation for natural catchments. In urban areas, check the hydraulic divide as well: kerbs, road camber and pipes can move water between topographic catchments.

Worked example: 35 ha residential catchment

A 35 ha (0.35 km²) catchment drains to a proposed culvert. It holds 24 ha of single-family housing, 7 ha of asphalt streets and 4 ha of parks, on medium-permeability soil and moderate slopes. Tc is 20 minutes, and the local IDF curve gives 95 mm/h for a 20-minute storm at the 1:10-year return period.

Composite coefficient, with values from the table below:

C=24(0.40)+7(0.83)+4(0.17)35=0.46C = \frac{24(0.40) + 7(0.83) + 4(0.17)}{35} = 0.46

Peak discharge:

Q=0.46×95×0.353.6=4.25 m3/sQ = \frac{0.46 \times 95 \times 0.35}{3.6} = 4.25\ \text{m}^3/\text{s}

The same catchment in US units is 86.5 acres with i = 3.74 in/h. The calculator returns 150.1 cfs, which is 4.25 m³/s; the hand form Q = CiA gives 148.8 cfs, the 0.8 % difference explained in the FAQ.

Raising C by 0.05 to 0.51 raises Q to 4.71 m³/s, an 11 % increase. That sensitivity is the reason to document how C was chosen. The culvert would be sized for 4.25 m³/s at the 1:10-year level of service, with any freeboard the governing standard requires; the culvert calculator takes it from there.

Runoff coefficient table

Typical C with the range in brackets, for moderate slopes, by soil permeability. These are the values in Studio’s coefficient lookup, compiled from the ASCE Manual of Practice for urban and paved surfaces and from standard references for rural cover.

Land useLow permeabilityMedium permeabilityHigh permeability
Single-family residential0.48 (0.40–0.55)0.40 (0.30–0.50)0.32 (0.25–0.40)
Multi-family or townhouse0.60 (0.50–0.70)0.50 (0.40–0.60)0.42 (0.35–0.50)
Apartments or condominiums0.70 (0.60–0.80)0.60 (0.50–0.70)0.55 (0.45–0.65)
High-density residential0.78 (0.70–0.85)0.70 (0.60–0.80)0.65 (0.55–0.75)
Downtown or central business district0.88 (0.80–0.95)0.82 (0.70–0.95)0.78 (0.65–0.90)
Neighbourhood commercial0.68 (0.60–0.75)0.60 (0.50–0.70)0.55 (0.45–0.65)
Shopping centre with parking0.80 (0.70–0.90)0.70 (0.60–0.80)0.65 (0.55–0.75)
Light industrial0.75 (0.65–0.85)0.67 (0.55–0.80)0.60 (0.50–0.70)
Heavy industrial0.85 (0.75–0.95)0.77 (0.65–0.90)0.70 (0.60–0.80)
Asphalt streets0.88 (0.80–0.95)0.83 (0.75–0.92)0.80 (0.70–0.90)
Concrete paving0.92 (0.85–0.98)0.88 (0.82–0.95)0.86 (0.80–0.92)
Rooftops0.88 (0.80–0.95)0.85 (0.78–0.93)0.82 (0.75–0.90)
Gravel roads and driveways0.52 (0.35–0.70)0.42 (0.25–0.60)0.30 (0.15–0.45)
Parks and landscaped gardens0.22 (0.15–0.30)0.17 (0.10–0.25)0.13 (0.08–0.18)
Playgrounds and sports fields0.32 (0.25–0.40)0.27 (0.20–0.35)0.22 (0.15–0.28)
Cultivated row crops0.45 (0.35–0.55)0.35 (0.25–0.45)0.25 (0.15–0.35)
Pasture and grassland0.32 (0.20–0.45)0.25 (0.15–0.35)0.18 (0.10–0.25)
Natural veld, scrub or bush0.35 (0.20–0.50)0.26 (0.12–0.40)0.18 (0.08–0.28)
Forest and woodland0.20 (0.10–0.30)0.13 (0.07–0.20)0.10 (0.05–0.15)
Bare or disturbed soil0.57 (0.40–0.75)0.45 (0.30–0.60)0.32 (0.20–0.45)

Steeper ground raises C: bare soil on medium-permeability soil goes from 0.35 on flat terrain to 0.55 on steep terrain, and single-family housing from 0.35 to 0.45.

Limitations and when to use something else

  • Peak only. There is no hydrograph and no volume, so the method cannot size storage. Build a hydrograph with the unit hydrograph generator or route a design storm through the detention pond calculator.
  • Uniform rainfall. Storm cells rarely cover a large catchment evenly for the whole of Tc. Above about 15 km² the assumption becomes non-conservative, and a hydrograph or regional method is the better choice. For South African sites, design flood estimation runs the SANRAL Rational procedure next to the unit hydrograph, SDF and regional methods.
  • No storage. Wetlands, dams and floodplains attenuate the peak, so the Rational Method overestimates where they are significant.
  • Constant C. Real losses fall as soils wet up. Some standards raise C for rarer return periods with a frequency factor; the calculator uses the C you enter, so apply any such factor yourself.
  • Tc sensitivity. Different Tc formulas give different durations and therefore different intensities.

What a free Studio account adds

Results on this page are free. A free Studio account adds:

  • Saving and reports: each calculation is filed under a project, with Word and Excel reports that set out C, i, A, the formula and the warnings.
  • The full coefficient lookup: 93 entries filtered by land use, slope class and soil permeability, each with its range and source.
  • Composite C built from sub-areas, each with its own coefficient.
  • A built-in Tc calculator with six methods to fix the storm duration, and a link to the IDF tool to read the intensity at that duration.
  • An areal reduction factor on intensity, entered by hand or taken from a saved ARF calculation.
  • Area from a saved watershed delineation, so the area in the report matches the mapped catchment.
FAQ

Common questions

What is the rational method formula?
Q = CiA, where C is the dimensionless runoff coefficient, i the rainfall intensity for a duration equal to the time of concentration, and A the catchment area. In SI units Q = CiA / 3.6 gives m³/s from mm/h and km², because 1 mm/h falling on 1 km² is 1/3.6 m³/s. In US units Q = CiA gives cfs from in/h and acres, with a hidden factor of 1.008 that practice rounds to 1.
What runoff coefficient should I use?
Read C from a table by land use, slope and soil permeability, then area-weight it if the catchment is mixed. Asphalt streets on medium-permeability soil take about 0.83, single-family housing on moderate slopes about 0.40, and parks about 0.17. C is the most judgement-heavy input and drives the result one for one, so for critical infrastructure lean towards the upper end of the tabulated range.
What is the maximum catchment area for the rational method?
The SANRAL Drainage Manual (6th ed., section 3.5.1.1 and Table 3.2) recommends the method only for catchments smaller than about 15 km², because it assumes uniform rainfall over the whole catchment for the duration of Tc, while allowing experienced engineers to use it on larger catchments in some cases. The calculator warns above 15 km². Local drainage manuals often set their own, lower limit, so check the one that governs your project.
How do I choose the rainfall intensity for the rational method?
Set the storm duration equal to the time of concentration, choose the return period your design standard requires, and read the intensity off the IDF curve for the site at that duration. A shorter Tc gives a higher intensity, so compute Tc carefully and with more than one method. The intensity must be in the same unit system as the formula: mm/h with the /3.6 form, in/h with acres.
Why does the calculator give 1.008 cfs for 1 in/h on 1 acre?
Because 1 inch per hour on 1 acre is exactly 1.008 cubic feet per second. The US form Q = CiA drops that factor, which understates Q by 0.8 %. The calculator converts every input to SI and back, so its US result carries the exact factor. In the worked example it reports 150.1 cfs where hand arithmetic with Q = CiA gives 148.8 cfs.
Does the rational method give a runoff volume or hydrograph?
No. It returns a single peak flow and says nothing about how long the peak lasts or how much water passes. For storage design you need a hydrograph: build one from the peak with a synthetic unit hydrograph shape, or use a rainfall-runoff method such as TR-55 with a design storm, then route it through the pond.
Full documentation: Rational Method Calculator
Every input, option and equation in the Studio tool, with its limitations.
Run it from your AI agent
This engine is open to Claude, ChatGPT, Cursor and other MCP clients as run_rational and lookup_runoff_coefficient. The agent passes the inputs, the engine does the calculation, and the record is saved to your project for you to review.

Reference tables

References

  1. Kuichling, E. (1889) The relation between the rainfall and the discharge of sewers in populous districts. Transactions of the American Society of Civil Engineers, 20, 1-56.
  2. ASCE (1992) Design and Construction of Urban Stormwater Management Systems. ASCE Manuals and Reports of Engineering Practice No. 77. American Society of Civil Engineers, New York.
  3. Chow, V.T., Maidment, D.R. and Mays, L.W. (1988) Applied Hydrology. McGraw-Hill, New York.
  4. SANRAL (2013) Drainage Manual, 6th ed. South African National Roads Agency SOC Ltd, Pretoria. Chapter 3: Hydrology.

Last reviewed by the Delta Hydro engineering team.