What the tool calculates
You place an outlet on the map. Studio delineates the catchment on a hydrologically corrected Copernicus GLO-30 (30 m) DEM, traces the longest watercourse and derives the parameters the South African methods need: area, the 10–85 slope, time of concentration, mean annual precipitation, land cover, soils, veld zone, SDF basin, RMF K-region and the NaFSAT 2.0 clusters. It then pulls the design rainfall and runs every method you ticked for the return periods you chose, from 1:2 to 1:200 years. The Studio tool runs for sites in South Africa only, because its rainfall grids and regional classifications stop at the border.
Before anything is charged, you see the delineated catchment and the outlet the engine actually used, and you confirm it. That step exists because a pin a short way off the channel, or on a tributary within about 150 m of a confluence, can return the wrong river’s catchment.
Most of the deterministic methods share the Rational form, with the SDF making the runoff coefficient depend on return period:
| Symbol | Meaning | Units |
|---|---|---|
| Peak discharge for return period | m³/s | |
| Runoff coefficient for return period | – | |
| Design rainfall intensity at duration | mm/h | |
| Catchment area | km² | |
| , | SDF basin calibration coefficients | % |
| Return-period factor, Drainage Manual Table 3.13 (0.84 at 1:5, 1.28 at 1:10, 2.05 at 1:50, 2.33 at 1:100) | – |
The methods in one run
| Method | Family | Output | Source |
|---|---|---|---|
| Rational, three rainfall alternatives | Deterministic | Peak, triangular hydrograph | Drainage Manual §3.5.1 |
| SCS-SA | Deterministic | Peak, hydrograph | Schmidt & Schulze (1987) |
| Standard Design Flood | Deterministic, regionally calibrated | Peak, triangular hydrograph, and a Van Bladeren (2005) adjusted peak where a sub-catchment matches | Alexander (2002) |
| Unit Hydrograph | Synthetic unit hydrograph | Peak, hydrograph | HRU Report 1/72 |
| Direct Runoff Hydrograph (DRH) | Storm-loss rainfall excess routed through a single linear reservoir (Muskingum, X = 0); no unit hydrograph | Peak, routed hydrograph | Bauer & Midgley (1974); DWS flood frequency guide (2025) §4.4 |
| RMF | Envelope | One maximum flood, no return period | Kovács (1988), Du Plessis & Masule (2023) |
| MIPI 7.1 | Empirical | Peak per return period, 1:10 to 1:100 only | Drainage Manual §3.6.3 |
| CAPA | Empirical | Peak per return period | McPherson (1983); DWS flood frequency guide (2025) §5.4 |
| Index Flood, PRM | Regional statistical | Peak per return period | Calitz & Smithers (2020), NaFSAT 2.0 |
| QRT | Regional statistical | Peak per return period | Calitz (2020), NaFSAT 2.0 |
The Rational run uses all three of the Drainage Manual’s rainfall sources: the Midgley & Pitman depth-duration-frequency curves (Alternative 1), TR102 station depths with the modified Hershfield equation (Alternative 2) and the RLMA&SI design-rainfall grid (Alternative 3). The runoff coefficient, area and are shared, so the spread between the three is the uncertainty that comes from the rainfall database alone.
Catchment-area limits
The method list is gated by area applicability ranges, judged against a preliminary catchment area. Above a hard upper bound the method is disabled. Below a lower bound it stays available and is flagged as indicative. The Rational, SCS-SA and Unit Hydrograph ranges are those of SANRAL Drainage Manual (6th ed.) Table 3.2. Table 3.2 sets no area limit on the SDF or the empirical methods; the 10 – 40 000 km² SDF range is the one Studio applies.
| Method | Recommended catchment area | Upper bound |
|---|---|---|
| Rational | < 15 km² (advisory, DM §3.5.1.1) | Flagged, still runs |
| Alternative Rational | < 15 km² (advisory, same as Rational) | Flagged, still runs |
| SCS-SA | ≲ 30 km² (advisory, Schmidt & Schulze 1987) | Flagged, still runs |
| SDF | 10 – 40 000 km² | Hard |
| Unit Hydrograph | 15 – 5 000 km² | Hard |
| DRH | 15 – 5 000 km² | Hard |
| RMF, MIPI 7.1, CAPA | Any size | None |
| Index Flood | Any size (advisory) | None |
| PRM | ≲ 50 000 km² (advisory, NaFSAT) | Flagged, still runs |
| QRT | 10 – 10 000 km² (advisory, NaFSAT) | Flagged, still runs |
The Drainage Manual also says MIPI 7.1 is suited to rural catchments larger than 100 km², so treat it as a check below that.
Why several methods are run and compared
No single South African method is calibrated for every catchment, and each family fails differently. The Rational and SCS-SA results depend on a runoff coefficient or curve number you can argue about. The SDF and unit hydrograph carry regional calibrations from older flood records. Index Flood, PRM and QRT were fitted to gauged rural floods and never see land cover. The RMF is an envelope above the largest recorded floods, so it bounds the others rather than competing with them.
When families built on different data agree, that agreement is the evidence for your design value. When they disagree, the pattern usually points at something specific about the catchment: urban cover, a dam upstream, dolomite, or an outlet near a cluster boundary. Studio puts every method on one table and one chart so the disagreement is visible before you choose.
Worked example
One road job, three outlets
A batch holds a 6.2 km² culvert catchment, a 26.4 km² stream crossing and a 7 200 km² river bridge, with every method ticked. The applicability check returns:
| Method | 6.2 km² | 26.4 km² | 7 200 km² |
|---|---|---|---|
| Rational | Runs | Flagged above 15 km² | Flagged |
| SCS-SA | Runs | Runs | Flagged above 30 km² |
| SDF | Flagged below 10 km² | Runs | Runs |
| Unit Hydrograph, DRH | Flagged below 15 km² | Runs | Not run (above 5 000 km²) |
| QRT | Flagged below 10 km² | Runs | Runs |
| RMF, MIPI 7.1, CAPA, Index Flood, PRM | Runs | Runs | Runs |
Each site runs the subset its own area allows, so the river bridge does not stop the culvert from getting a unit hydrograph check.
The regional cross-check on the 26.4 km² catchment
This catchment lies east of Pretoria. The delineation gave = 26.45 km², MAP = 725 mm and = 2.14 h, the 1:10-year 24-hour point rainfall is 97.8 mm, and the centroid sits 4.20 decimal degrees from the coast in NaFSAT cluster 31. Running the regional methods on those inputs gives:
| Method | 1:10 (m³/s) | 1:50 (m³/s) | 1:100 (m³/s) |
|---|---|---|---|
| PRM | 34.6 | 73.4 | 97.6 |
| Index Flood | 19.3 | 37.8 | 47.6 |
| QRT | 20.4 | 24.0 | 24.2 |
| RMF 2023 (K = 4.8, envelope) | 314 | 314 | 314 |
Index Flood and QRT agree at 1:10, then the three methods spread to a factor of four at 1:100. The land cover from the delineation is about 68 % urban, and none of the three regional methods can see that. Here the design value has to lean on the Rational and SCS-SA results, which do respond to impervious cover, with the regional methods as a rural baseline and the RMF as a ceiling.
Inputs and where they come from
You supply the outlet, the methods and the return periods. Outlets can be clicked on the map, pasted as coordinates, uploaded as a point layer (GeoJSON, Shapefile, KML, KMZ or GeoPackage) or taken from a saved watershed delineation. Everything else is derived, and an expert can override the parts that matter most: the Kovács correction, the rainfall region for Alternative 1, the SCS-SA storm type, lag and rainfall duration, the RMF K-value, the NaFSAT cluster, the QRT DR10% and the coast distance.
Limitations and when to use something else
- The catchment comes from a 30 m DEM and cannot be edited in the tool. Where piped urban drainage decides the boundary, draw your own catchment and use the Rational Method calculator.
- The regional statistical methods were calibrated on rural gauged catchments. Urban cover, large dams and dolomite are outside their calibration.
- Where a reliable gauge record exists at or near the site, at-site flood frequency analysis should carry more weight than any regional method. The stream gauge finder shows what records exist.
- The RMF is an envelope and not a design flood. For dams, take the RMF and the PMF into a dam safety evaluation.
- Hydrographs come from the Rational, SDF, SCS-SA, unit hydrograph and DRH methods. The empirical and regional methods return peaks only, so a storage or routing study needs one of the hydrograph methods, or the unit hydrograph generator on your own inputs.
What the full Studio tool adds
A submission can hold up to 200 outlets, with a bulk discount from 10 sites. Each site gets its own result page, and a batch page compares the peak flows by site with a CSV export. The results page puts every method on one peak-flow table and chart with a flood frequency curve, plots the hydrographs for each return period, and lets you hide a method from the view or set it aside with a written reason in the engineer’s review. Every finished estimate downloads as a Word report and an Excel workbook, with the catchment and watercourse as GeoJSON or Shapefile.
The price depends on the delineated catchment area and is shown on the confirmation step before you submit. You can save a half-finished request as a draft, and resubmit a finished one with changed parameters. The Index Flood method, the probabilistic rational method, the QRT calculator and the regional maximum flood also exist as standalone calculators for catchments you have delineated elsewhere.
Common questions
Which flood method should I use for a SANRAL road project?
What is the standard design flood (SDF)?
How do you estimate peak flow for an ungauged catchment in South Africa?
Why do the methods give such different answers?
Can I run a design flood estimate outside South Africa?
What do I get when the estimate is finished?
quote_flood_estimate, submit_flood_estimate, submit_flood_batch and get_flood_request. The agent passes the inputs, the engine does the calculation, and the record is saved to your project for you to review.
References
- SANRAL (2013) Drainage Manual, 6th ed. South African National Roads Agency SOC Ltd, Pretoria. Chapter 3, Flood Hydrology.
- Alexander, W.J.R. (2002) The Standard Design Flood. Journal of the South African Institution of Civil Engineering, 44(1), 26–30.
- Smithers, J.C. (2012) Methods for design flood estimation in South Africa. Water SA, 38(4), 633–646.
- Hydrological Research Unit (1972) Design flood determination in South Africa. HRU Report 1/72, University of the Witwatersrand, Johannesburg.
- Schmidt, E.J. and Schulze, R.E. (1987) Flood volume and peak discharge from small catchments in Southern Africa, based on the SCS technique. WRC Report TT 31/87, Water Research Commission, Pretoria.
- Du Plessis, J.A. and Masule, S. (2023) Revised Regional Maximum Flood (RMF) method and regionalisation. Journal of the South African Institution of Civil Engineering, 65(3), 2–19.
- Calitz, J.P. and Smithers, J.C. (2020) Development and Assessment of Regionalised Approaches to Design Flood Estimation in South Africa. WRC Report No. 2748/1/20, Water Research Commission, Pretoria.
- Calitz, J.P. (2020) Development and assessment of regionalised approaches to design flood estimation in South Africa. PhD thesis, University of KwaZulu-Natal, Pietermaritzburg.
- McPherson, D.R. (1983) Comparison of mean annual flood peaks calculated by various methods. Technical Report TR119, South African National Hydrology Symposium Proceedings. Department of Environment Affairs and WRC, Pretoria.
- Department of Water and Sanitation (2025) A Guide to Flood Frequency Estimation Methods as Applied in the DWS, 11th ed. (version 2). DWS, Pretoria.
Last reviewed by the Delta Hydro engineering team.